*Available to customers in Canada and the US. Step 1 GFCI Outlet Find the breaker box and switch off the breaker that is labelled 'GFCI receptacle' If not sure, switch off all breakers. If you require any further assistance, please contact Customer Service. Be sure to protect the plug from rain/snow. If water gets into the GFCI plug, it will cause it to trip. Please also ensure that the plug makes full contact with the outlet. Your spa should be plugged directly into a dedicated household outlet to reduce chances of damage. NOTE: Do not plug the GFCI into an extension cord. Common reasons could be bad wiring, old or defective outlets, and the end of the lifespan. But, you have an issue if there is no power despite the light. If your GFCI’s green light is on, the outlet or the breaker has gone through a self-test and passed. Be sure to remove the plastic cover from the plug prongs and test the plug in a standard household outlet (press "Reset" to turn on). Replace the old outlets with the new ones. Step 6: Apply the cover plate and tighten the 4 screws. Step 5: Install the cable clamp (2 screws) making sure the clamp is holding the black casing (rather than touching the 3 wires). I just put up a new light fixture outside, so I think I can replace an outlet or light switch. I have basic electrical knowledge, enough to shut off breakers, use voltage tester to verify if a wire is hot and screw a wire in. I also want to add GFCI protection to bathroom outlets near sink. Step 4: Insert the wires into the correct terminals (Black to Brass, Green to Green, White to Bright) and tighten the screws. Kitchen needs 2 new outlets at counter level. Step 3: Remove the cable and make sure there is enough exposed wire to be inserted into the terminals. Step 2: Loosen the 3 terminal screws enough to release the wires then remove the 2 screws along with the cable clamp securing the cord. Step 1: Remove the 4 screws securing the cover plate to the shell and lift off the plate. Simply install the existing cord by inserting the wires into the terminals of the new shell. If you are replacing your previous GFCI Head with the In-line GFCI, the 20 ft cord can simply be removed and stored away as it will not be needed. NOTE: The new In-line GFCI will have a 20ft cord attached to the shell. Over time the GFCI will need to be replaced depending on use and environment. It shuts off an electric circuit when it detects that current is flowing along an unintended path, possibly through water or through a person. This is an instructional guide outlining the steps to install the In-Line Auto-Reset Ground Fault Circuit Interrupter* for all Plug & Play Spas (includes Portables and Acrylics).Īlso applicable for those who are replacing the older GFCI Head with the In-Line version.Ī Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD) is a device used to reduce the risk of electric shock. Modified on: Thu, 13 Dec, 2018 at 5:22 PM The buttons on the GFCI outlet don’t work if the buttons on a GFCI outlet are unresponsive, it’s a sign that the outlet needs to be replaced. Solution home Service Solutions GFCI Plugs 120V GFCI - How to Replace the In-Line GFCI
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |